Item | Specification |
---|---|
Motorcraft® MERCON® LV Automatic Transmission Fluid XT-10-QLVC (US); CXT-10-LV12 (Canada) | MERCON® LV |
Removal
It is necessary to note the location of the main control wire harness connectors so they can be connected in the same positions. Connector color letters are cast into the solenoid body.
Remove the main control ground wire bolt. Disconnect the electrical connectors and remove the main control wiring harness.
Note the locations of the 2 long bolts.
Remove the main control valve body and accumulators.
Each accumulator is equipped with 2 springs. All 4 springs are different sizes.
NOTE:
Note the size and location of the accumulator springs to aid assembly.
NOTE:
Note the shape of each piston and the piston bore from which the piston was removed. The shape and size will vary depending on application. The piston must be installed in its correct bore during assembly.
Remove the accumulator pistons and springs.Installation
The thin longer springs are for the neutral and drive accumulator.
NOTE:
Accumulator bore and pistons are matched by depth; some pistons may have steps. Install the pistons in the same bore as removed.
Install the accumulator pistons and springs.
NOTE:
Do not fully tighten the main control valve bolts at this stage.
Install the main control valve body.It is necessary to connect the electrical connectors in the same positions as noted in disassembly. Connector color letters are cast into the solenoid body.
Install the main control valve wiring harness, connect the electrical connectors and install the main control ground wire bolt.
Ford Focus Catalyst Monitor Sensor
Special Tool(s)
Socket, Exhaust Gas Oxygen Sensor
303-476 (T94P-9472-A)
Material
Item
Specification
High Temperature Nickel Anti-Seize Lubricant
XL-2
ESE-M12A4-A